89 research outputs found

    Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants

    Get PDF
    The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. Statement of significance: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient\u27s age and disease status

    The clinical, radiological, microbiological, and molecular profile of the skin-penetration site of transfemoral amputees treated with bone-anchored prostheses.

    Get PDF
    The breach of the skin barrier is a critical issue associated with the treatment of individuals with transfemoral amputation (TFA) using osseointegrated, percutaneous titanium implants. Thirty TFA patients scheduled for abutment exchange or removal were consecutively enrolled. The aims were to determine the macroscopic skin signs, the presence of bacteria and the gene expression in abutment-adherent cells and to conduct correlative and comparative analyses between the different parameters. Redness and a granulation ring were present in 47% of the patients. Bacteria were detected in 27/30 patients, commonly in the bone canal. Staphylococcus aureus, coagulase-negative staphylococci, streptococci, and Enterococcus faecalis were the most common. A positive correlation was found between TNF-α expression and the detection of S. aureus. Staphylococcus aureus together with other bacterial species revealed a positive relationship with MMP-8 expression. A negative correlation was demonstrated between the length of the residual femur bone and the detection of a granulation ring and E. faecalis. A positive correlation was revealed between fixture loosening and pain and the radiological detection of endosteal bone resorption. Fixture loosening was also correlated with the reduced expression of interleukin-10 and osteocalcin. It is concluded that several relationships exist between clinical, radiological, microbiological, and molecular assessments of the percutaneous area of TFAs. Further long term studies on larger patient cohorts are required to determine the precise cause-effect relationships and unravel the role of host-bacteria interactions in the skin, bone canal and on the abutment for the longevity of percutaneous implants as treatment of TFA. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 578-589, 2017

    Inflammatory cell response to ultra-thin amorphous and crystalline hydroxyapatite surfaces

    Get PDF
    It has been suggested that surface modification with a thin hydroxyapatite (HA) coating enhances the osseointegration of titanium implants. However, there is insufficient information about the biological processes involved in the HA-induced response. This study aimed to investigate the inflammatory cell response to titanium implants with either amorphous or crystalline thin HA. Human mononuclear cells were cultured on titanium discs with a machined surface or with a thin, 0.1 mu m, amorphous or crystalline HA coating. Cells were cultured for 24 and 96 h, with and without lipopolysaccharide (LPS) stimulation. The surfaces were characterized with respect to chemistry, phase composition, wettability and topography. Biological analyses included the percentage of implant-adherent cells and the secretion of pro-inflammatory cytokine (TNF-alpha) and growth factors (BMP-2 and TGF-beta 1). Crystalline HA revealed a smooth surface, whereas the amorphous HA displayed a porous structure, at nano-scale, and a hydrophobic surface. Higher TNF-alpha secretion and a higher ratio of adherent cells were demonstrated for the amorphous HA compared with the crystalline HA. TGF-beta 1 secretion was detected in all groups, but without any difference. No BMP-2 secretion was detected in any of the groups. The addition of LPS resulted in a significant increase in TNF-alpha in all groups, whereas TGF-beta 1 was not affected. Taken together, the results show that thin HA coatings with similar micro-roughness but a different phase composition, nano-scale roughness and wettability are associated with different monocyte responses. In the absence of strong inflammatory stimuli, crystalline hydroxyapatite elicits a lower inflammatory response compared with amorphous hydroxyapatite

    Electropolished Titanium Implants with a Mirror-Like Surface Support Osseointegration and Bone Remodelling

    Get PDF
    This work characterises the ultrastructural composition of the interfacial tissue adjacent to electropolished, commercially pure titanium implants with and without subsequent anodisation, and it investigates whether a smooth electropolished surface can support bone formation in a manner similar to surfaces with a considerably thicker surface oxide layer. Screw-shaped implants were electropolished to remove all topographical remnants of the machining process, resulting in a thin spontaneously formed surface oxide layer and a smooth surface. Half of the implants were subsequently anodically oxidised to develop a thickened surface oxide layer and increased surface roughness. Despite substantial differences in the surface physicochemical properties, the microarchitecture and the composition of the newly formed bone were similar for both implant surfaces after 12 weeks of healing in rabbit tibia. A close spatial relationship was observed between osteocyte canaliculi and both implant surfaces. On the ultrastructural level, the merely electropolished surface showed the various stages of bone formation, for example, matrix deposition and mineralisation, entrapment of osteoblasts within the mineralised matrix, and their morphological transformation into osteocytes. The results demonstrate that titanium implants with a mirror-like surface and a thin, spontaneously formed oxide layer are able to support bone formation and remodelling

    Loads at the implant-prosthesis interface during free and aided ambulation in osseointegrated transfemoral prostheses

    Get PDF
    Bone-anchored attachment of amputation limb prostheses is increasingly becoming a clinically accepted alternative to conventional socket suspension. The direct transfer of loads demands that the percutaneous implant system and the residual bone withstand all forces and moments transferred from the prosthesis. This study presents load measurements recorded at the bone-anchored attachment in 20 individuals with unilateral transfemoral amputation performing the everyday ambulatory activities: level ground walking, stairs ascent/descent and slope ascent/descent. Mean peak values for the sample populations across activities ranged from 498–684 N for the resultant force, 26.5–39.8 Nm for the bending moment, and 3.1–5.5 Nm for the longitudinal moment. Significant differences with respect to level walking were found for the resultant force during stairs ascent, (higher, p = 0.002), and stairs descent, (lower, p = 0.005). Using a crutch reduced the peak resultant forces and the peak bending moments with averages ranging from 5.5–12.6 % and 13.2–15.6 %, respectively. Large inter-participant variations were observed and no single activity resulted in consistently higher loading of the bone-anchored attachment across the participants. Results from this study can guide future development of percutaneous osseointegrated implant systems for limb prostheses and their rehabilitation protocols

    Effects of radiation therapy on tissue and serum concentrations of tumour associated trypsin inhibitor and their prognostic significance in rectal cancer patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We have previously demonstrated that elevated concentrations of tumour-associated trypsin inhibitor (TATI) in both tumour tissue (t-TATI) and in serum (s-TATI) are associated with a poor prognosis in colorectal cancer patients. It was also found that s-TATI concentrations were lower in patients with rectal cancer compared to patients with colon cancer. In this study, we investigated the effects of neoadjuvant radiotherapy (RT) on concentrations of t-TATI and s-TATI in patients with rectal cancer.</p> <p>Methods</p> <p>TATI was analysed in serum, normal mucosa and tumour tissue collected at various time points in 53 rectal cancer patients enrolled in a case-control study where 12 patients received surgery alone, 20 patients 5 × 5 Gy (short-term) preoperative RT and 21 patients 25 × 2 Gy (long-term) preoperative RT. T-TATI was analysed by immunohistochemistry and s-TATI was determined by an immunofluorometric assay. Mann-Whitney U test and Wilcoxon Z (Z) test were used to assess t-TATI and s-TATI concentrations in relation to RT. Spearman's correlation (R) test was used to explore the associations between t-TATI, s-TATI and clinicopathological parameters. Overall survival (OS) according to high and low t-TATI and s-TATI concentrations was estimated by classification and regression tree analysis, Kaplan-Meier analysis and the log rank test.</p> <p>Results</p> <p>RT did not affect concentrations of t-TATI or s-TATI. In patients receiving short-term but not long-term RT, s-TATI concentrations were significantly higher 4 weeks post surgery than in serum drawn prior to surgery (Z = -3.366, P < 0.001). T-TATI expression correlated with male gender (R = 0.406, P = 0.008). High t-TATI expression in surgical specimens was associated with a significantly shorter OS (P = 0.045). S-TATI concentrations in serum drawn at all time points were associated with an impaired OS (P = 0.035 before RT, P = 0.001 prior to surgery, P = 0.043 post surgery). At all time points, s-TATI correlated with higher age (P < 0.001-0.021) and with increased s-creatinine concentrations assessed prior to surgery (P = 0.041).</p> <p>Conclusions</p> <p>The results presented here further validate the utility of t-TATI and s-TATI as prognostic biomarkers in patients with rectal cancer, independent of neoadjuvant RT.</p
    • …
    corecore